Rayonix : X-ray Instruments for Crystallography and Diffraction
PRODUCTS

SX Series X-ray DETECTOR SYSTEM

SX-165 detector: SX165, SX Series, MarCCD, Mar165, Mar 165, CCD165, CCD 165 detector, 165mm CCD The SX Series are the only CCD X-ray detectors that are ideal for both synchrotrons and rotating anode X-ray sources. The SX-165 features a round, 165 mm diameter active area, and a versatile, high-resolution CCD chip.

The SX-165 is the upgraded version of the very successful MarCCD X-ray detector. From macromolecular crystallography to Small Angle X-ray Scattering (SAXS), the MarCCD is known throughout the world for unsurpassed imaging and excellent reliability. The SX-165 retains the same design and construction as the MarCCD, but features a modernized and improved controller, and higher gain. It also has a frameshift mode of readout for time-resolved imaging on the order of milliseconds. The SX-165 can be used with or without the MarDTB goniostat and MarCSC Cryogenic Sample Changer.

 Single Chip, Large Detecting Surface

The SX-165 uses one 4kx4k chip, permanently bonded to a single fiber-optic taper, for simplicity and reliability. The monolithic design features a large, 165mm diameter circular taper imaged on a square CCD chip.

 Low Noise, Fast Readout

Custom electronics provide extremely low readout noise at high readout speeds. The SX-165 reads the chip from four channels simultaneously, resulting in a 2048x2048 pixel image in 2.5 seconds with less read noise than any comparable detector system.

 Low Temperature, Low Dark Current

The CCD chip in the SX-165 is cooled to -70°C and protected inside a sealed vacuum chamber. The resulting dark current, less than 0.01e-/pixel/sec., allows exposures long enough for data collection from any crystal on any X-ray source. The refrigeration system requires only a standard electrical outlet and no cooling water.

 Factory Calibration

The SX-165 is correctly calibrated before delivery. Due to the permanent bond between the fiber-optic taper and the CCD chip, the instrument does not require routine recalibration.

 Time-Resolved Imaging in Milliseconds

A newly-developed optional mode of data collection with the SX-165 makes taking data frames separated by only milliseconds possible. Frame-shift mode uses part of the CCD chip for imaging and the rest for data storage. After collecting the first image in the sequence, the CCD is triggered to quickly shift a configurable number of pixel rows, exposing fresh rows for the next image. Further triggers can make the CCD shift again and again until the CCD is filled up. It then reads out the entire CCD at the standard rate, and produces a corrected image showing a collage of the separate exposures.

 Complete System

The SX-165 system includes a computer workstation with data collection software installed, configured, and ready to use. The system also includes the Automar crystallographic data processing suite. When combined with a MarDTB goniostat (or MarDTB/MarCSC), the system is ready to collect data immediately. If the SX-165 is installed on another goniostat, our engineers can help design custom software to support it.

 Knowledgeable Customer Support

When you call us, you talk directly with experienced, knowledgeable technical staff-the same scientists and engineers who design, build, and service the instrument.

 Affordability

The SX-165 is very reasonably priced. Contact us for a quotation based on your specific needs.

Toll-free: 1-1-877-627-XRAY (1-877-627-9729)
Outside the U.S.: +1-847-869-1548
Fax: 1-847-869-1587
E-mail: info@rayonix.com

Download the SX Series Spec Sheet for details.

Get a quotation now by filling out our Online Quote Request Form.

 


IMAGE CAPTION:
Image taken with MX-225 X-ray Detector System.

 
 
|  GET QUOTE  |  EMAIL US  |  SITE MAP  |
Rayonix LLC © 2007 | Toll Free: 1-877-627-XRAY (1-877-627-9729) | Outside the U.S.: +1-847-869-1548